Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 57
Filter
1.
ACS Sens ; 9(4): 1896-1905, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38626402

ABSTRACT

With the escalating global awareness of air quality management, the need for continuous and reliable monitoring of toxic gases by using low-power operating systems has become increasingly important. One of which, semiconductor metal oxide gas sensors have received great attention due to their high/fast response and simple working mechanism. More specifically, self-heating metal oxide gas sensors, wherein direct thermal activation in the sensing material, have been sought for their low power-consuming characteristics. However, previous works have neglected to address the temperature distribution within the sensing material, resulting in inefficient gas response and prolonged response/recovery times, particularly due to the low-temperature regions. Here, we present a unique metal/metal oxide/metal (MMOM) nanowire architecture that conductively confines heat to the sensing material, achieving high uniformity in the temperature distribution. The proposed structure enables uniform thermal activation within the sensing material, allowing the sensor to efficiently react with the toxic gas. As a result, the proposed MMOM gas sensor showed significantly enhanced gas response (from 6.7 to 20.1% at 30 ppm), response time (from 195 to 17 s at 30 ppm), and limit of detection (∼1 ppm) when compared to those of conventional single-material structures upon exposure to carbon monoxide. Furthermore, the proposed work demonstrated low power consumption (2.36 mW) and high thermal durability (1500 on/off cycles), demonstrating its potential for practical applications in reliable and low-power operating gas sensor systems. These results propose a new paradigm for power-efficient and robust self-heating metal oxide gas sensors with potential implications for other fields requiring thermal engineering.


Subject(s)
Gases , Nanowires , Oxides , Nanowires/chemistry , Gases/chemistry , Gases/analysis , Oxides/chemistry , Metals/chemistry
2.
Proc Natl Acad Sci U S A ; 121(14): e2400868121, 2024 Apr 02.
Article in English | MEDLINE | ID: mdl-38547066

ABSTRACT

Partial cystectomy procedures for urinary bladder-related dysfunction involve long recovery periods, during which urodynamic studies (UDS) intermittently assess lower urinary tract function. However, UDS are not patient-friendly, they exhibit user-to-user variability, and they amount to snapshots in time, limiting the ability to collect continuous, longitudinal data. These procedures also pose the risk of catheter-associated urinary tract infections, which can progress to ascending pyelonephritis due to prolonged lower tract manipulation in high-risk patients. Here, we introduce a fully bladder-implantable platform that allows for continuous, real-time measurements of changes in mechanical strain associated with bladder filling and emptying via wireless telemetry, including a wireless bioresorbable strain gauge validated in a benchtop partial cystectomy model. We demonstrate that this system can reproducibly measure real-time changes in a rodent model up to 30 d postimplantation with minimal foreign body response. Studies in a nonhuman primate partial cystectomy model demonstrate concordance of pressure measurements up to 8 wk compared with traditional UDS. These results suggest that our system can be used as a suitable alternative to UDS for long-term postoperative bladder recovery monitoring.


Subject(s)
Urinary Bladder , Urinary Tract Infections , Animals , Humans , Urinary Bladder/surgery , Urodynamics/physiology , Prostheses and Implants , Cystectomy
4.
Small ; 20(2): e2304555, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37649204

ABSTRACT

Toxic gases have surreptitiously influenced the health and environment of contemporary society with their odorless/colorless characteristics. As a result, a pressing need for reliable and portable gas-sensing devices has continuously increased. However, with their negligence to efficiently microstructure their bulky supportive layer on which the sensing and heating materials are located, previous semiconductor metal-oxide gas sensors have been unable to fully enhance their power efficiency, a critical factor in power-stringent portable devices. Herein, an ultrathin insulation layer with a unique serpentine architecture is proposed for the development of a power-efficient gas sensor, consuming only 2.3 mW with an operating temperature of 300 °C (≈6% of the leading commercial product). Utilizing a mechanically robust serpentine design, this work presents a fully suspended standalone device with a supportive layer thickness of only ≈50 nm. The developed gas sensor shows excellent mechanical durability, operating over 10 000 on/off cycles and ≈2 years of life expectancy under continuous operation. The gas sensor detected carbon monoxide concentrations from 30 to 1 ppm with an average response time of ≈15 s and distinguishable sensitivity to 1 ppm (ΔR/R0 = 5%). The mass-producible fabrication and heating efficiency presented here provide an exemplary platform for diverse power-efficient-related devices.

5.
ACS Nano ; 17(23): 23649-23658, 2023 Dec 12.
Article in English | MEDLINE | ID: mdl-38039345

ABSTRACT

The high explosiveness of hydrogen gas in the air necessitates prompt detection in settings where hydrogen is used. For this reason, hydrogen sensors are required to offer rapid detection and possess superior sensing characteristics in terms of measurement range, linearity, selectivity, lifetime, and environment insensitivity according to the publicized protocol. However, previous approaches have only partially achieved the standardized requirements and have been limited in their capability to develop reliable materials for spatially accessible systems. Here, an electrical hydrogen sensor with an ultrafast response (∼0.6 s) satisfying all demands for hydrogen detection is demonstrated. Tailoring structural engineering based on the reaction kinetics of hydrogen and palladium, an optimized heating architecture that thermally activates fully suspended palladium (Pd) nanowires at a uniform temperature is designed. The developed Pd nanostructure, at a designated temperature distribution, rapidly reacts with hydrogen, enabling a hysteresis-free response from 0.1% to 10% and durable characteristics in mechanical shock and repetitive operation (>10,000 cycles). Moreover, the device selectively detects hydrogen without performance degradation in humid or carbon-based interfering gas circumstances. Finally, to verify spatial accessibility, the wireless hydrogen detection system has been demonstrated, detecting and reporting hydrogen leakage in real-time within just 1 s.

6.
Nat Med ; 29(12): 3137-3148, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37973946

ABSTRACT

The human body generates various forms of subtle, broadband acousto-mechanical signals that contain information on cardiorespiratory and gastrointestinal health with potential application for continuous physiological monitoring. Existing device options, ranging from digital stethoscopes to inertial measurement units, offer useful capabilities but have disadvantages such as restricted measurement locations that prevent continuous, longitudinal tracking and that constrain their use to controlled environments. Here we present a wireless, broadband acousto-mechanical sensing network that circumvents these limitations and provides information on processes including slow movements within the body, digestive activity, respiratory sounds and cardiac cycles, all with clinical grade accuracy and independent of artifacts from ambient sounds. This system can also perform spatiotemporal mapping of the dynamics of gastrointestinal processes and airflow into and out of the lungs. To demonstrate the capabilities of this system we used it to monitor constrained respiratory airflow and intestinal motility in neonates in the neonatal intensive care unit (n = 15), and to assess regional lung function in patients undergoing thoracic surgery (n = 55). This broadband acousto-mechanical sensing system holds the potential to help mitigate cardiorespiratory instability and manage disease progression in patients through continuous monitoring of physiological signals, in both the clinical and nonclinical setting.


Subject(s)
Intensive Care Units, Neonatal , Infant, Newborn , Humans , Monitoring, Physiologic
7.
PLoS One ; 18(11): e0294948, 2023.
Article in English | MEDLINE | ID: mdl-38019868

ABSTRACT

Preterm birth (PTB) refers to delivery before 37 weeks of gestation. Premature neonates exhibit higher neonatal morbidity and mortality rates than term neonates; therefore, it is crucial to predict and prevent PTB. Advancements enable the prediction and prevention of PTB using genetic approaches, especially by investigating its correlation with single nucleotide polymorphisms (SNPs). We aimed to identify impactive and relevant SNPs for the prediction of PTB via whole-genome sequencing analyses of the blood of 31 pregnant women with PTB (n = 13) and term birth (n = 18) who visited the Ewha Womans University Mokdong Hospital from November 1, 2018 to February 29, 2020. A genome-wide association study was performed using PLINK 1.9 software and 256 SNPs were selected and traced through protein-protein interactions. Moreover, a validation study by genotyping was performed on 60 other participants (preterm birth, n = 30; term birth, n = 30) for 25 SNPs related to ion channel binding and receptor complex pathways. Odds ratios were calculated using additive, dominant, and recessive genetic models. The risk of PTB in women with the AG allele of rs2485579 (gene name: RYR2) was significantly 4.82-fold increase, and the risk of PTB in women with the AG allele of rs7903957 (gene name: TBX5) was significantly 0.25-fold reduce. Our results suggest that rs2485579 (in RYR2) can be a genetic marker of PTB, which is considered through the association with abnormal cytoplasmic Ca2+ concentration and dysfunctional uterine contraction due to differences of RYR2 in the sarcoplasmic reticulum.


Subject(s)
Premature Birth , Humans , Female , Pregnancy , Infant, Newborn , Premature Birth/genetics , Premature Birth/prevention & control , Pregnant Women , Genome-Wide Association Study , Ryanodine Receptor Calcium Release Channel/genetics , Republic of Korea
8.
Biosens Bioelectron ; 237: 115545, 2023 Oct 01.
Article in English | MEDLINE | ID: mdl-37517336

ABSTRACT

Temperature is the most commonly collected vital sign in all of clinical medicine; it plays a critical role in care decisions related to topics ranging from infection to inflammation, sleep, and fertility. Most assessments of body temperature occur at isolated anatomical locations (e.g. axilla, rectum, temporal artery, or oral cavity). Even this relatively primitive mode for monitoring can be challenging with vulnerable patient populations due to physical encumbrances and artifacts associated with the sizes, weights, shapes and mechanical properties of the sensors and, for continuous monitoring, their hard-wired interfaces to data collection units. Here, we introduce a simple, miniaturized, lightweight sensor as a wireless alternative, designed to address demanding applications such as those related to the care of neonates in high ambient humidity environments with radiant heating found in incubators in intensive care units. Such devices can be deployed onto specific anatomical locations of premature infants for homeostatic assessments. The estimated core body temperature aligns, to within 0.05 °C, with clinical grade, wired sensors, consistent with regulatory medical device requirements. Time-synchronized, multi-device operation across multiple body locations supports continuous, full-body measurements of spatio-temporal variations in temperature and additional modes of determining tissue health status in the context of sepsis detection and various environmental exposures. In addition to thermal sensing, these same devices support measurements of a range of other essential vital signs derived from thermo-mechanical coupling to the skin, for applications ranging from neonatal and infant care to sleep medicine and even pulmonary medicine.

9.
Proc Natl Acad Sci U S A ; 120(9): e2219394120, 2023 02 28.
Article in English | MEDLINE | ID: mdl-36802437

ABSTRACT

Vocal fatigue is a measurable form of performance fatigue resulting from overuse of the voice and is characterized by negative vocal adaptation. Vocal dose refers to cumulative exposure of the vocal fold tissue to vibration. Professionals with high vocal demands, such as singers and teachers, are especially prone to vocal fatigue. Failure to adjust habits can lead to compensatory lapses in vocal technique and an increased risk of vocal fold injury. Quantifying and recording vocal dose to inform individuals about potential overuse is an important step toward mitigating vocal fatigue. Previous work establishes vocal dosimetry methods, that is, processes to quantify vocal fold vibration dose but with bulky, wired devices that are not amenable to continuous use during natural daily activities; these previously reported systems also provide limited mechanisms for real-time user feedback. This study introduces a soft, wireless, skin-conformal technology that gently mounts on the upper chest to capture vibratory responses associated with vocalization in a manner that is immune to ambient noises. Pairing with a separate, wirelessly linked device supports haptic feedback to the user based on quantitative thresholds in vocal usage. A machine learning-based approach enables precise vocal dosimetry from the recorded data, to support personalized, real-time quantitation and feedback. These systems have strong potential to guide healthy behaviors in vocal use.


Subject(s)
Singing , Voice Disorders , Voice , Humans , Feedback , Voice Disorders/etiology , Voice/physiology , Vocal Cords/physiology
10.
Proc Natl Acad Sci U S A ; 120(6): e2217828120, 2023 02 07.
Article in English | MEDLINE | ID: mdl-36716364

ABSTRACT

Thermal sensations contribute to our ability to perceive and explore the physical world. Reproducing these sensations in a spatiotemporally programmable manner through wireless computer control could enhance virtual experiences beyond those supported by video, audio and, increasingly, haptic inputs. Flexible, lightweight and thin devices that deliver patterns of thermal stimulation across large areas of the skin at any location of the body are of great interest in this context. Applications range from those in gaming and remote socioemotional communications, to medical therapies and physical rehabilitation. Here, we present a set of ideas that form the foundations of a skin-integrated technology for power-efficient generation of thermal sensations across the skin, with real-time, closed-loop control. The systems exploit passive cooling mechanisms, actively switchable thermal barrier interfaces, thin resistive heaters and flexible electronics configured in a pixelated layout with wireless interfaces to portable devices, the internet and cloud data infrastructure. Systematic experimental studies and simulation results explore the essential mechanisms and guide the selection of optimized choices in design. Demonstration examples with human subjects feature active thermoregulation, virtual social interactions, and sensory expansion.


Subject(s)
Skin , Virtual Reality , Humans , Electronics , Thermosensing , Communication
11.
Sci Adv ; 8(51): eade3201, 2022 12 23.
Article in English | MEDLINE | ID: mdl-36563148

ABSTRACT

Recently reported winged microelectronic systems offer passive flight mechanisms as a dispersal strategy for purposes in environmental monitoring, population surveillance, pathogen tracking, and other applications. Initial studies indicate potential for technologies of this type, but advances in structural and responsive materials and in aerodynamically optimized geometries are necessary to improve the functionality and expand the modes of operation. Here, we introduce environmentally degradable materials as the basis of 3D fliers that allow remote, colorimetric assessments of multiple environmental parameters-pH, heavy metal concentrations, and ultraviolet exposure, along with humidity levels and temperature. Experimental and theoretical investigations of the aerodynamics of these systems reveal design considerations that include not only the geometries of the structures but also their mass distributions across a range of bioinspired designs. Preliminary field studies that rely on drones for deployment and for remote colorimetric analysis by machine learning interpretation of digital images illustrate scenarios for practical use.

12.
NPJ Digit Med ; 5(1): 147, 2022 Sep 20.
Article in English | MEDLINE | ID: mdl-36123384

ABSTRACT

Swallowing is a complex neuromuscular activity regulated by the autonomic nervous system. Millions of adults suffer from dysphagia (impaired or difficulty swallowing), including patients with neurological disorders, head and neck cancer, gastrointestinal diseases, and respiratory disorders. Therapeutic treatments for dysphagia include interventions by speech-language pathologists designed to improve the physiology of the swallowing mechanism by training patients to initiate swallows with sufficient frequency and during the expiratory phase of the breathing cycle. These therapeutic treatments require bulky, expensive equipment to synchronously record swallows and respirations, confined to use in clinical settings. This paper introduces a wireless, wearable technology that enables continuous, mechanoacoustic tracking of respiratory activities and swallows through movements and vibratory processes monitored at the skin surface. Validation studies in healthy adults (n = 67) and patients with dysphagia (n = 4) establish measurement equivalency to existing clinical standard equipment. Additional studies using a differential mode of operation reveal similar performance even during routine daily activities and vigorous exercise. A graphical user interface with real-time data analytics and a separate, optional wireless module support both visual and haptic forms of feedback to facilitate the treatment of patients with dysphagia.

13.
ACS Nano ; 16(8): 11957-11967, 2022 Aug 23.
Article in English | MEDLINE | ID: mdl-35621510

ABSTRACT

Palladium (Pd) has been drawing increasing attention as a hydrogen (H2) detecting material due to its highly selective sensitivity to H2. However, at H2 concentrations above 2%, Pd undergoes an inevitable phase transition, causing undesirable electrical and mechanical alterations. In particular, nonlinear gas response (ΔR/R0) that accompanies phase transition has been a great bottleneck for detecting H2 in high concentrations, which is especially important as there is a risk of explosion over 4% H2. Here, we propose a phase-transition-inhibited Pd nanowire H2 sensor that can detect up to 4% H2 with high linearity and high sensitivity. Based on the calculation of the change in free energy, we designed Pd nanowires that are highly adhered to the substrate to withstand the stress that leads to phase transition. We theoretically optimized the Pd nanowire dimensions using a finite element method simulation and then experimentally fabricated the proposed sensor by exploiting a developed nanofabrication method. The proposed sensor exhibits a high sensing linearity (98.9%) with high and stable sensitivity (ΔR/R0/[H2] = 875%·bar-1) over a full range of H2 concentrations (0.1-4%). Using the fabricated Pd sensors, we have successfully demonstrated a wireless sensor module that can detect H2 with high linearity, notifying real-time H2 leakage through remote communication. Overall, our work suggests a nanostructuring strategy for detecting H2 with a phase-transition-inhibited pure Pd H2 sensor with rigorous scientific exploration.

14.
Proc Natl Acad Sci U S A ; 118(43)2021 10 26.
Article in English | MEDLINE | ID: mdl-34663725

ABSTRACT

Early identification of atypical infant movement behaviors consistent with underlying neuromotor pathologies can expedite timely enrollment in therapeutic interventions that exploit inherent neuroplasticity to promote recovery. Traditional neuromotor assessments rely on qualitative evaluations performed by specially trained personnel, mostly available in tertiary medical centers or specialized facilities. Such approaches are high in cost, require geographic proximity to advanced healthcare resources, and yield mostly qualitative insight. This paper introduces a simple, low-cost alternative in the form of a technology customized for quantitatively capturing continuous, full-body kinematics of infants during free living conditions at home or in clinical settings while simultaneously recording essential vital signs data. The system consists of a wireless network of small, flexible inertial sensors placed at strategic locations across the body and operated in a wide-bandwidth and time-synchronized fashion. The data serve as the basis for reconstructing three-dimensional motions in avatar form without the need for video recordings and associated privacy concerns, for remote visual assessments by experts. These quantitative measurements can also be presented in graphical format and analyzed with machine-learning techniques, with potential to automate and systematize traditional motor assessments. Clinical implementations with infants at low and at elevated risks for atypical neuromotor development illustrates application of this system in quantitative and semiquantitative assessments of patterns of gross motor skills, along with body temperature, heart rate, and respiratory rate, from long-term and follow-up measurements over a 3-mo period following birth. The engineering aspects are compatible for scaled deployment, with the potential to improve health outcomes for children worldwide via early, pragmatic detection methods.


Subject(s)
Infant Behavior/physiology , Monitoring, Physiologic/instrumentation , Movement/physiology , Vital Signs/physiology , Wireless Technology/instrumentation , Bias , Child , Equipment Design , Heart Rate , Humans , Imaging, Three-Dimensional , Infant , Miniaturization , Monitoring, Physiologic/statistics & numerical data , Respiratory Rate , Skin , Video Recording , Wireless Technology/statistics & numerical data
15.
Clin Exp Vaccine Res ; 10(2): 141-147, 2021 May.
Article in English | MEDLINE | ID: mdl-34222126

ABSTRACT

PURPOSE: The aims of the present study were to evaluate the immunogenicity of an inactivated rabies vaccine based on the ERAGS strain. MATERIALS AND METHODS: The ERAGS virus propagated in Vero cells was inactivated with 3 mM binary ethylenimine for 8 hours. Three types of inactivated rabies vaccines were prepared to determine the minimum vaccine virus titers. Four further types of inactivated rabies vaccines were prepared by blending inactivated ERAGS with four different adjuvants; each vaccine was injected into mice, guinea pigs, and dogs to identify the optimal adjuvant. The immunogenicity of a Montanide (IMS) gel-adjuvanted vaccine was evaluated in cats, dogs, and cattle. Humoral immune responses were measured via a fluorescent antibody virus neutralization method and a blocking enzyme-linked immunosorbent assay. RESULTS: The minimum virus titer of the inactivated rabies vaccine was over 107.0 50% tissue culture infectious doses (TCID50 values)/mL. Of the four kinds of adjuvants, the IMS gel-adjuvanted vaccine induced the highest mean viral neutralizing antibody (VNA) titers of 6.24 and 2.36 IU/mL in guinea pigs and dogs, respectively, and was thus selected as the vaccine for the target animals. Cats, dogs, and cattle inoculated with the IMS gel-adjuvanted vaccine developed protective VNA titers ranging from 3.5 to 1.2 IU/mL at 4 weeks post-inoculation (WPI). CONCLUSION: Our data indicate that cats, dogs, and cattle inoculated with an inactivated rabies vaccine derived from the ERAGS strain developed protective immune responses that were maintained to 12 WPI.

16.
J Vet Sci ; 22(4): e56, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34313041

ABSTRACT

BACKGROUND: Fluorescent antibody virus neutralization (FAVN) test is a standard assay for quantifying rabies virus-neutralizing antibody (VNA) in serum. However, a safer rabies virus (RABV) should be used in the FAVN assay. There is a need for a new method that is economical and time-saving by eliminating the immunostaining step. OBJECTIVES: We aimed to improve the traditional FAVN method by rescuing and characterizing a new recombinant RABV expressing green fluorescent protein (GFP). METHODS: A new recombinant RABV expressing GFP designated as ERAGS-GFP was rescued using a reverse genetic system. Immuno-fluorescence assay, peroxidase-linked assay, electron microscopy and reverse transcription polymerase chain reaction were performed to confirm the recombinant ERAGS-GFP virus as a RABV expressing the GFP gene. The safety of ERAGS-GFP was evaluated in 4-week-old mice. The rabies VNA titers were measured and compared with conventional FAVN and FAVN-GFP tests using VERO cells. RESULTS: The virus propagated in VERO cells was confirmed as RABV expressing GFP. The ERAGS-GFP showed the highest titer (108.0 TCID50/mL) in VERO cells at 5 days post-inoculation, and GFP expression persisted until passage 30. The body weight of 4-week-old mice inoculated intracranially with ERAGS-GFP continued to increase and the survival rate was 100%. In 62 dog sera, the FAVN-GFP result was significantly correlated with that of conventional FAVN (r = 0.95). CONCLUSIONS: We constructed ERAGS-GFP, which could replace the challenge virus standard-11 strain used in FAVN test.


Subject(s)
Antibodies, Neutralizing/immunology , Antibodies, Viral/immunology , Gene Expression Regulation, Viral/physiology , Green Fluorescent Proteins/metabolism , Rabies virus/genetics , Viral Proteins/metabolism , Animals , Cell Line , Chlorocebus aethiops , Cricetinae , Green Fluorescent Proteins/genetics , Rabies virus/immunology , Rabies virus/metabolism , Viral Proteins/genetics
17.
Sci Rep ; 11(1): 2392, 2021 01 27.
Article in English | MEDLINE | ID: mdl-33504832

ABSTRACT

Preterm birth (PTB), defined as birth at less than 37 weeks of gestation, is a major determinant of neonatal mortality and morbidity. Early diagnosis of PTB risk followed by protective interventions are essential to reduce adverse neonatal outcomes. However, due to the redundant nature of the clinical conditions with other diseases, PTB-associated clinical parameters are poor predictors of PTB. To identify molecular signatures predictive of PTB with high accuracy, we performed mRNA sequencing analysis of PTB patients and full-term birth (FTB) controls in Korean population and identified differentially expressed genes (DEGs) as well as cellular pathways represented by the DEGs between PTB and FTB. By integrating the gene expression profiles of different ethnic groups from previous studies, we identified the core T-cell activation pathway associated with PTB, which was shared among all previous datasets, and selected three representative DEGs (CYLD, TFRC, and RIPK2) from the core pathway as mRNA signatures predictive of PTB. We confirmed the dysregulation of the candidate predictors and the core T-cell activation pathway in an independent cohort. Our results suggest that CYLD, TFRC, and RIPK2 are potentially reliable predictors for PTB.


Subject(s)
Gene Expression Profiling , Lymphocyte Activation/genetics , Premature Birth/etiology , T-Lymphocytes/metabolism , Transcriptome , Adult , Cohort Studies , Computational Biology/methods , Disease Susceptibility , Female , Gene Ontology , Gene Regulatory Networks , Humans , Infant, Newborn , Pregnancy , Risk Factors , T-Lymphocytes/immunology
18.
ACS Nano ; 14(12): 16813-16822, 2020 Dec 22.
Article in English | MEDLINE | ID: mdl-33263256

ABSTRACT

This study proposes a reliable and self-powered hydrogen (H2) gas sensor composed of a chemo-mechanically operating nanostructured film and photovoltaic cell. Specifically, the nanostructured film has a configuration in which an asymmetrically coated palladium (Pd) film is coated on a periodic polyurethane acrylate (PUA) nanograting. The asymmetric Pd nanostructures, optimized by a finite element method simulation, swell upon reacting with H2 and thereby bend the PUA nanograting, changing the amount of transmitted light and the current output of the photovoltaic cell. Since the degree of warping is determined by the concentration of H2 gas, a wide concentration range of H2 (0.1-4.0%) can be detected by measuring the self-generated electrical current of the photovoltaic cell without external power. The normalized output current changes are ∼1.5%, ∼2.8%, ∼3.5%, ∼5.0%, ∼21.5%, and 25.3% when the concentrations of H2 gas are 0.1%, 0.5%, 1.0%, 1.6%, 2%, and 4%, respectively. Moreover, because Pd is highly chemically reactive to H2 and also because there is no electrical current applied through Pd, the proposed sensor can avoid device failure due to the breakage of the Pd sensing material, resulting in high reliability, and can show high selectivity against various gases such as carbon monoxide, hydrogen sulfide, nitrogen dioxide, and water vapor. Finally, using only ambient visible light, the sensor was modularized to produce an alarm in the presence of H2 gas, verifying a potential always-on H2 gas monitoring application.

19.
J Vet Sci ; 21(5): e64, 2020 Sep.
Article in English | MEDLINE | ID: mdl-33016015

ABSTRACT

BACKGROUND: Canine distemper virus (CDV) infection results in high morbidity and mortality in dogs. There has been no report about isolation of Korean CDV since 1980 in Korea. OBJECTIVES: To investigate the biological properties and the genetic characterization of Korean CDV. METHODS: Vero cells expressing dog signaling lymphocyte activation molecule (dSLAM) gene named as Vero/dSLAM were used to isolate CDV using 17 samples. Diagnostic methods such as cytopathic effects, immunofluorescence assay, peroxidase linked assay, electron microscopy, rapid immunodiagnostic assay, and reverse transcription polymerase chain reaction were used to confirm the Korean CDV isolate as a CDV. The genetic analysis was performed through cloning and sequencing of hemagglutinin gene of CDV isolate. RESULTS: A virus propagated in Vero/dSLAM cell was confirmed as CDV (CD1901 strain) based on the above methods. The CD1901 strain showed the highest viral titer (105.5 50% tissue culture infectious dose [TCID50]/mL) in the Vero/dSLAM cells at 4 days post inoculation, but did not form a fork on chorioallantoic membrane of 7-day-old egg. Ribavirin, a nucleotide analogue anti-viral agent, inhibits moderately the Korean CDV propagation in the Vero/dSLAM cells. The nucleotide and amino acid sequences of the H gene of CD1901 strain were compared with those of other CDV strains. The CD1901 strain belonged to Asia 1 group and had the highest similarity (99.9%) with the BA134 strain, which was isolated in China in 2008. CONCLUSIONS: We constructed successfully Vero/dSLAM and isolated one Korean CDV isolate (CD1901 strain) from a naturally infected dog. The CD1901 strain belonged to Asia 1 genotype.


Subject(s)
Distemper Virus, Canine/physiology , Signaling Lymphocytic Activation Molecule Family Member 1/chemistry , Animals , Chlorocebus aethiops , Distemper/virology , Distemper Virus, Canine/genetics , Distemper Virus, Canine/isolation & purification , Dog Diseases/virology , Dogs , Republic of Korea , Vero Cells
20.
J Vet Sci ; 21(4): e63, 2020 Jul.
Article in English | MEDLINE | ID: mdl-32735100

ABSTRACT

BACKGROUND: Canine adenovirus type 2 (CAV-2) induces infectious laryngotracheitis in members of the family Canidae, including dogs. To date, no ELISA kits specific for CAV-2 antibody have been commercialized for dogs in Korea. OBJECTIVES: We aimed to develop new indirect enzyme-linked immunosorbent assay (I-ELISA) to perform rapid, accurate serological surveys of CAV-2 in dog serum samples. METHODS: In total, 165 serum samples were collected from dogs residing in Chungbuk and Gyeongbuk provinces between 2016 and 2018. The Korean CAV-2, named the APQA1701-40P strain, was propagated in Madin-Darby canine kidney cells and purified in an anion-exchange chromatography column for use as an antigen for I-ELISA. The virus-neutralizing antibody titers of CAV-2 in the dog sera were measured by virus neutralization (VN) test. RESULTS: We compared the results obtained between the VN and new I-ELISA tests. The sensitivity, specificity, and accuracy of new I-ELISA were 98.6%, 86.4% and 97.0% compared with VN test, respectively. New I-ELISA was significantly correlated with VN (r = 0.91). CONCLUSIONS: These results indicate that new I-ELISA is useful for sero-surveillance of CAV-2 in dog serum.


Subject(s)
Adenoviridae Infections/veterinary , Adenoviruses, Canine/isolation & purification , Dog Diseases/immunology , Enzyme-Linked Immunosorbent Assay/veterinary , Adenoviridae Infections/immunology , Animals , Antibodies, Viral/blood , Dogs , Enzyme-Linked Immunosorbent Assay/methods , Republic of Korea , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...